Custom Search
 
  
 
TM 55-1905-223-10
c.
Waterjet Shutdown.
NOTE
Before waterjet shutdown, ensure thrust direction indicator is in aft position.
(1) Set BOWTHRUSTER/FIRE PUMP THROTTLE/CLUTCH (1, FIGURE 2-155) to center position
(neutral position) and allow engine to idle for 3 to 5 minutes.
(2) On bowthruster Waterjet Control Panel (FIGURE 2-156) set Hydraulic pump ON switch (4) to OFF
position.
(3) Turn key (1) counterclockwise to off position and remove key.
(4) On Bridge Console Panel (FIGURE 2-157), press BOWTHRUSTER ENGINE STOP pushbutton (2).
FIGURE 2-157. Bridge Console Panel.
2-442


 