Custom Search
 
  
 
TM 55-1905-223-10
FIGURE 2-166. TYPE-I Motor Switch.
(e) Check the output by pening the top inspection cover. Close top inspection cover.
o
(f) Slowly open LO-11, PURIFIER SUCTION (32) until glass bowl is approximately 1/2 full.
(g) Allow L.O. Purifier to purify oil for 4 hours per engine.
(3)
L.O. Purifier and L.O. Purifier Preheater Shutdown.
(a) On Lube Oil Heater Switch (FIGURE 2-164) press STOP pushbutton (2) and
set LOCK (3) by sliding LOCK (3) upward.
(b) Close LO-11, PURIFIER SUCTION (32, FIGURE 2-167).
(c) Wait 1 minute.
(d) On L.O. Purifier TYPE-I Motor S itch (FIGURE 2-166) press STOP pushbutton (2) and set LOCK
w
(3) by sliding LOCK (3) upward.
(e) Close all valves in the Lube Oil Purification and Transfer piping system (FIGURE 2-167).
(f) On Auxiliary Machinery Motor Control Center (FIGURE 2-167) set L.O. PURIFIER circuit breaker
(1)
and L.O. PURIFIER HEATER circuit breaker (2) to OFF position.
2-466


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business