TM 55-1905-223-10
(b) F-3S, open FO-25 and FO-22, SUCT FR TK F-3S (40 and 54).
(c)
F-4P, open FO-24 and FO-19, SUCT FR TK F-4P (42 and 52)..
(d) F-4S, open FO-23 and FO-20, SUCT FR TK F-4S (41 and 47).
(e) F-7P, open FO-28 and FO-15, SUCT FR TK F-7P (21 and 50).
(f)
F-7S, open FO-27 and FO-16, SUCT FR TK F-7S (19 and 49).
(g) F-12P, open FO-34 and FO-18, SUCT FR DAY TK F-12P (24 and 48).
(h) F-12S, open FO-35 and FO-17, SUCT FR DAY TK F-12S (16 and 51).
(i)
Operate NO. 1 XFR PUMP and NO. 2 XFR PUMP by pressing START Push Button (1,
been removed. Press STOP Push Button (2).
(11) Close all valves in Fuel Oil Filter, Transfer, and Supply Piping System.
(12) Disconnect fueling hose from deck connection.
CAUTION
The Oil Water Separator Piping System may not produce a legally acceptable oil
free water effluent if the water contains soap, deter- gents, bilge cleaners, protein-
foam, or similar agents. The rated capacity of the system is the maximum flow
rate with clean filter elements and 0 psi back pressure.
CAUTION
Do not run water having temperature above 130 (55 ) through the OCA-1A
F
C
Sensing Module, as high temperatures may affect the accuracy of the PPM
reading.
a.
System Startup Operation.
(1) Close all valves in Oil Water Separator Piping System (FIGURE 2-171).
(2) Open valves OWS-1, BILGE SUCTION (2) and OWS-2, BILGE SUCTION (4).
(3) Open OWS-5, 1ST STAGE SUCT (21).
(4) Open OWS-11, 1ST STAGE PRESS GAUGE (7).
(5) Open OWS-9, 2ND STAGE PRESS GAUGE (11).
(6) Open OWS-6, DISCH TO SLTTDGE TK (20).
(7) Open OWS-13, OIL RETURN TO 1ST STAGE (13).
Change 2 2-484
|
||