TM 55-1905-223-10
NOTE
If engine is cold, advance CHOKE control (5) fully clockwise (closed), then half
open as engine starts, and fully open for running.
(5) Press and hold START Push Button (4) until engine starts. Adjust choke and speed controls as
required.
CAUTION
Do not allow pump to run more than 2 minutes without water flowing. Lack of
cooling water could cause severe impeller and exhaust system damage.
(6) Open water discharge valve (3, FIGURE 2-200) slowly and advance engine SPEED control (6,
FIGURE 2-201) as required to attain desired pumping pressure.
(7) Place OFF-START-RUN switch (2) in RUN position.
(8) Rotate CHOKE control (5) to full counterclockwise position.
d. Shutdown Procedure.s
(1) Rotate SPEED control (6, FIGURE 2-201) to full counterclockwise idle position.
(2) Place OFF-START-RUN switch (2) in OFF position.
(3) Open pump drain valve (4, FIGURE 2-200) fully counterclockwise. Keep open until drained.
(4) Flush pump with fresh water.
(a) Place suction hose with foot valve and strainer into fresh water supply.
(b) Prime pump until full, inspect for leaks.
(c) Shut discharge valve.
WARNING
Ensure exhaust gases discharge to outside atmosphere.
(d) Start engine. Switch to start; advance speed slightly; press start button; choke as needed.
(e) Prime pump; push priming buttons and hold, when water discharges from priming pump; ensure
discharge hose is manned; open water discharge valve slowly. Release priming button.
NOTE
Primer pump should evacuate air from impeller housing and suction hose in
approximately 60 seconds.
Change 2 2-548


 