Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-10
b. Shutdown Water Purification System.
(1) Set ON-OFF POWER switch (2, FIGURE 2-229) to OFF position.
(2) Set S1 POWER SWITCH (1) to OFF position.
(3) Close BB-22, ISLN-SEA CHEST (11).
(4) Close FWM-1, ISLN-SW SUPPLY TO FW MAKERS (12, FIGURE 2-228).
(5) Close FWM-2, SW SUPPLY TO FW MAKER NO. 2 (15).
(6) Close FWM-3, SW SUPPLY TO FW MAKER NO. 1 (17).
(7) Close FWM-4, BRINE OBVD DISCH (1).
(8) Close FW-4, FW MAKER NO. 2 SUPPLY TO FW TKS (18).
(9) Close FW-5, FW MAKER NO. 1 SUPPLY TO FW TANKS (19).
(10) Close FW-3, FILL ISLN-TK FW-6S (6).
(11) Close FW-2, FILL ISLN-TK FW-6P (5).
a. Press STOP pushbutton (2), set P205-9 circuit breaker (1) to OFF position.
b. Press STOP pushbutton (4), set P205-10 circuit breaker (3) to OFF position.
c. Press STOP pushbutton (27), set P205-11 circuit breaker (28) to OFF position
d. Press STOP pushbutton (25), set P205-12 circuit breaker (26) to OFF position.
e. Set P205-14A (23) and P205-14B circuit breakers (24) to OFF position.
f. Set P205-13A (21) and P205-13B circuit breakers (22) to OFF position.
g. Press STOP pushbutton (6), set P205-1 circuit breaker (5) to OFF position.
h. Press STOP pushbutton (17), set P205-2 circuit breaker (20) to OFF position.
i. Press STOP pushbutton (18), set P205-3 circuit breaker (19) to OFF position.
j. Press STOP pushbutton (8), set P205-6 circuit breaker (7) to OFF position.
k. Press STOP pushbutton (10), set P205-7 circuit breaker (9) to OFF position.
1. Press STOP pushbutton (12), set P205-8 circuit breaker (11) to OFF position.
m. Press STOP pushbutton (14), set P205-4 circuit breaker (13) to OFF position.
n. Press STOP pushbutton (16), set P205-5 circuit breaker (15) to OFF position.
|
||