WARNING
The FM-200 system has been outfitted with a time delay override
located on top of the time delay.
When the time delay override lever is pulled, the 60 second time
delay is negated and FM-200 will immediately discharge into the
protected spaces.
This procedure should only be performed under extreme circum-
stances and with the authority of the watch officer or scene
commander.
Failure to observe these warnings could result in death or serious
injury.
Operate the WWS for a minimum of fifteen (15) minutes. During the WWS operating
period, approximately every three (3) minutes, open valve WWS-2, Tunnel WWS Strainer
Blow Off for approximately ten (10) seconds. This will allow foreign matter to be flushed
from the strainer basket.
WARNING
To reduce temperatures within the protected space and manage
the risk of HF exposure to humans, the WWS is designed and
intended to be operated for a minimum of 15 minutes. This
procedure should be followed to the full extent or death or
serious injury could occur.
NOTE
The tunnel FM-200 System is augmented with an installed WWS. If
necessary, the FM-200 System could be used as a stand alone system.
d. Actuation Procedures, Bow Thruster Room FM-200 System. All fire scenarios and situations
leading to the decision when to actuate the FM-200 total flooding fire extinguishing system are
not intended to be discussed here. Refer to the US Army Fire Fighting Doctrine for guidance.
However, the following steps must be completed to effectively deploy the FM-200 System as
designed.
In the event the FM-200 Fixed Fire Fighting System is to be actuated, the following steps must
be accomplished prior to actuation of the system.
WARNING
In the event the FM-200 System electric horn/strobe or warning
lights (amber strobe) are activated, leave the protected space
immediately. FM-200 is being released within 60 seconds, death
or serious injury could occur.
(1)
Evacuate All Personnel From Space. The Watch Officer or on-scene commander must
ensure all personnel have evacuated the space and are accounted for.
(2)
Activate the Water Washdown System (WWS). In order to operate the WWS, the fire
main system must be charged. Ensure that the two (2) Engine Room Fire Pumps are
placed on line to the maximum operating pressure.
2-728