TM 55-1905-223-10
i.
Fixed Fire Fighting System (Paint Locker):
Condition: Inspect and observe pressure in tanks, securements, and releases.
Check vessel records for
accomplishment of annual servicing and 5 year inspection.
Standard: Pressure (adjusted for temperature) in normal range. No damage or corrosion or dislocation in
securements and release mechanism. Check vessel records accomplishment of annual weight test of cylinders
(C02) and performance of CFR required 5 year inspection procedures (hydro static cylinders).  NOTE:
Complete inspection and servicing of the fixed fire fighting system is normally included in OCCM specifications:
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
j.
Vents (Supply):
Condition: Inspect for condition of inlet screens, noise and vibration, access plates and fasteners, and
corrosion.
Standard: Screen in good condition, no excessive noise or vibration from fans, access plates and fasteners
present and in good Condition: No excessive corrosion. __________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
k.
Overflow Vents, Ballast and Fuel Tanks:
Condition: Inspect to insure screens are present and in serviceable condition, check for damage, verify that
color coding is IAW TB 43-0144, catchment basin present.
Standard: Screens present and undamaged and clear, no damage, painted IAW TB 43-0144, Catchment basin
installed below vent. _____________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
l.
Flood Lights:
Condition: Inspect for operation and damage and evidence of leakage.
Change 8 G-54


 