TM 55-1905-223-10
Standard: Lights light, no damage to case or lens, no evidence of leakage is present. ___________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
m.
Davits:
Condition: Inspect for damage and operation Condition: Check certification.
Standard: No damage, davit free to rotate in socket. (Certification good.) ____________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
n.
Fuel Oil Fill Stations (Port and Stbd):
Condition: Inspect to see that all caps and retained chains are present, secure, catchment present and free of
debris, drain plugs present, valves, paint proper color. Inspect operation of emergency fuel oil cutoff wrench
and valve.
Standard: Caps and retaining chains present, retaining chains present, secure and in good condition, catchment
present, free of debris, drain plugs fitted, valves operate freely, all components painted IAW TB 43-0144. ___
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
o.
Fresh Water Fill Hose and Cabinet:
Condition: Hose present, blue color, proper identification, cabinet condition and placard spanner wrench.
Inspect shut off valve operation.
Standard: Hose is present, in good condition, is blue color, marked "Potable Water", cabinet latch and hinges in
good Condition: Identification placard installed, spanner wrench present, shut off valve operates freely. _____
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
Change 8 G-55


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business