Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-10
Standard: Unit operates, accepts, shares and transfers load, responds to speed and load sharing controls
smoothly and without hesitation or surging. Frequency is maintained substantially constant over load range.
Overspeed trip operates to shut down unit. Fuel oil, lube oil, engine cooling water and exhaust systems are
leak free. Pressure and temperatures are within normal ranges, oil pressure minimum 18 psi, at idle, 45 psi at
1800 RPM, water temperature less than 215F at full load. No abnormal lube oil analysis reports or excessive
oil consumption. P/M services listed above have been accomplished as applicable (annual services at interim
inspection, annual and bi-annual inspections at the Pre-OCCM inspection. ____________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
i.
Reduction Gear Cooling Pumps:
Condition: Observe during operation for vibration, noise, leaks and maintenance of 30 psi pressure.
Standard: Operational, with no excessive vibration or noise, 30 psi pressure is maintained, shaft gland and
piping, pipe joints and flanges are leak free. ___________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
j.
Marine Sanitation System and Surge Tank:
Condition: Verify operational condition, inspect for evidence of leaks.
Standard: Fully operational, valves, pumps and piping systems are leak free. _________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
k.
Prelube Pump:
Condition: Verify operational condition, inspect valves, pumps and associated piping for evidence of leaks.
Change 8 G-76
|
||