Custom Search
 
  
 
TM 55-1905-223-24-11
(2) Pumps. The dataplates on all pumps are located on the pump motor housings.
1-8.
Equipment Data.
The following is the general equipment data for the sanitation device and all
associated components.
a. Sanitation Device.
Model Orca II 24, by Envirovac Inc.
Capacity:
Sewage ................................................................................................720 gl per day
Persons .................................................................................................................. 24
Dimensions and Weights:
Height ......................................................................................................... 42 inches
Width .......................................................................................................... 18 inches
Length ......................................................................................................... 38 inches
Dry Weight ....................................................................................................... 670 lb
Wet Weight ...................................................................................................... 885 lb
Allowable Pitch and Roll ..................................................................................30 degrees
Allowable Hydrostatic Head. ............................................................................ 10 ft water
Hypochlorite Requirement .........................................................................1.50 gl per day
External Piping Connections:
Sewage Inlet ............................................................................................3 in (FNPT)
Sewage Outlet (at discharge pump).......................................................3/4 in (FNPT)
Vent Outlet .........................................................................................1-1/2 in (FNPT)
Backwash Inlet ......................................................................................1/2 in (FNPT)
Input........................................................... 110/220 Vac, 1-phase, 50/60 Hz, 30 amp
Current Draw ............................................................................. 115/220 Vac, 3.5 kva
b. Associated Components.
Treatment Tank .........................................................................................Capacity, 14 gl
Sedimentation Modules:
Quantity ................................................................................................................... 2
Capacity .................................................................................................. 4.78 gl each
Waste Disposer:
Waste King, Model WK-750-1-SM ....................................3/4 hp, 115/230 Vac, 60 Hz
Flow Pump and Motor:
1-4


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business