b. Remove hardware securing C-face adapter (4) to motor (1).
c. Attach lifting sling to motor (1) at eye bolt (6).
d. Separate motor (1) from hydraulic pump (5) by pulling motor and pump apart. The two parts of flexible shaft
coupling (3) will separate.
e. Remove motor.
REPLACEMENT
a. Align motor (1) and one part of flexible shaft coupling (3) on motor shaft to pump (5) and other part of flexible
shaft coupling (3). Secure coupling to shafts with four hex screws (2).
b. Secure C-face adapter (4) to motor (1) with mounting hardware.
c. Replace hydraulic pump/motor assembly, paragraph 2-17.
d. Fill reservoir, paragraph 2-13.
e. Connect electrical power to windlass, restore windlass to operation, paragraph 2-13.