Custom Search
 
  
 
TM 55-1905-223-24-15
2-18. Replace Alternating Current Motor. (FIGURE 2-7)
This task covers: a. Removal, b. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
Windlass inoperative (para. 2-13).
Electrical power removed from
Lifting sling P/N 3375957
hydraulic power pack and tagged
"Out of Service."
Materials/Parts
Reservoir drained (para. 2-13).
Hydraulic power pack assembly
Alternating current motor
(pump/motor assy.) removed (para.
P/N 10J98Z65-286TC
Wiping rags, Item 1, Appendix C
Electrical ID Tags, Item 7,
General Safety Instruction
Don't touch power cables with the
sling.
WARNING
Alternating current motor is heavy. Use a lifting sling and lifting fixture to remove and replace
the motor or serious personal injury may occur.
CAUTION
The spline teeth on the pump shaft may be damaged by careless handling. Remove and replace
flexible shaft coupling carefully.
NOTE
Access to the flexible shaft coupling is through an inspection hole in the bottom of the C-face
adapter between the pump and motor.
REMOVAL
a. Gaining access through C-face adapter (4) bottom opening, loosen four hex screws (2) securing flexible shaft
coupling (3) to pump (5) and motor (1) shafts.
2-26


 