(4) Attach fluid filter head (2) to coupling (3).
(5) Connect the relief valve hydraulic line (14) to the coupling (3).
(6) Screw filter element (18) onto head (2). Secure 1/2 turn after gasket on filter contacts filter body.
h. Install Inspection Cover and Gasket.
(1) Replace the inspection cover gaskets (10) to the reservoir, right and left sides.
(2) Replace the inspection cover (9), right and left sides, and secure with attaching bolts (8).
i. Operational Check.
(1) Refill hydraulic reservoir, paragraph 2-13.
(2) Restore electrical power to hydraulic power pack assembly and remove tags.
(3) Operate the windlass and check for proper operation, paragraph 2-13. Check for leaks.