Custom Search
 
  
 
TM 55-1905-223-24-15
WARNING
Be sure the piston is pointed away from the operator during disassembly and assembly or
personal injury could occur.
High pressure compressed air tanks, piping systems, and air operated devices possess potential
for serious injury to the eyes and exposed areas of the skin due to escaping air pressure.
CAUTION
Do not apply static air pressure in excess of 15 psi MAXIMUM to the assembly or damage to the
assembly could occur.
(2) Apply 15 psi air pressure to the power plate air fitting to release brake pressure.
(3) Join the power plate and the piston. Release air pressure.
m. Replace the ball bearing (3) on the power plate end of the assembly.
n. Replace the retaining ring (2) on the power plate end of the assembly.
o. Replace the screws (19). Torque alternately to 75-85 ft-lb (102-116 N ).
m
p. Replace the failsafe brake assembly on the bow anchor windlass, paragraph 2-15.
q. Restore the bow anchor windlass to operating condition, paragraph 2-13.
r. Operate the windlass, check the operation of the failsafe brake assembly.
4-29


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business