Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-16
(3)
Connect couplers (40) at directional control valve (22) outlet port and fluid filter head (13).
l.
Cover Caskets, Reservoir Inspection Covers.
(1)
Install inspection cover (31) and gaskets (33) on each end.of reservoir.
(2)
Use suitable size wrench and turn cover bolt (30) clockwise to secure gasket and cover to reservoir. Repeat
installation procedure for inspection cover at ac motor end of reservoir.
(3)
Fill reservoir with hydraulic fluid.
CAUTION
To prevent possible damage to the internal parts, the pump should never be
started dry or without internal lubrication.
(4)
Disconnect coupler (1) from fitting (2) at top of hydraulic pump (18).
(5)
Disconnect fitting (2) at top port of hydraulic pump.
(6)
Fill pump housing with hydraulic fluid.
(7)
Replace fitting (2) at top port of hydraulic pump.
(8)
Connect coupler (1) to fitting (2).
m. Restore equipment to operational condition (Reference TM 55-1905-223-10).