Preventive Maintenance Checks and Services - Cont.
Table 2-1.
S - S e m i a n n u a l l y A - Annually
Q - Quarterly
D - Daily
W
-
Weekly
M
-
Monthly
Items To Be
Interval
Item
Procedures
Inspected/
No.
D
W
M
Q
S
A
Serviced
COMMISSARY AND LAUNDRY - CONT
Inspect condenser coil to make sure that air flow is
38
l
not hampered and that it is clear of dust and debris.
/Freezers
a. Inspect and clean drain line.
l
b.
Check the liquid refrigerant sight glass to ensure
system is fully charged.
c. Wipe down the interior liner with a mild soap and warm
water solution.
d.
Check condenser fan motor and evaporator fan motor to
ensure that they are operational and fans are tight and
secure.
e. Wipe door gaskets and breaker strips with a damp cloth.
f.
Clean exterior with mild soap and warm water. Dry
thoroughly.
l
a. Slide condensing unit from compartment and check all
f i t t i n g s for signs of leaks or fatigue.
b.
Inspect electrical connectins to ensure there is good
contact and wires are not frayed.


 