Preventive Maintenance Checks and Services - Cont.
Table 2-1.
A - Annually
S - Semiannually
Q - Quarterly
D - Daily W - Weekly W - Monthly
Items To Be
Interval
Item
Procedures
Inspected/
No.
D
W
M
Q
S
A
Serviced
ELECTRICAL SYSTEM - CONT
q
Power
53
(6) Close or reinstall access covers.
Distribution
Panels - CONT
(7) Remove safety tags.
(8) Return equipment to readiness condition.
q
a. Deenergize/disconnect battery chargers, where
Battery
54
applicable, and tag "Out of Service - Do Not Operate."
Storage
Group
WARNING
Observe NO SMOKING regulations.
Clean and Inspect Battery.
b.
(1) Clean battery with a lint-free towel dampened in
baking soda and distilled water solution.
(2) Rinse battery with distilled water.
(3) Dry battery with a lint-free towel.
(4) Inspect case for cracks and evidence of leakage.
(5) Inspect terminal posts, cable connectors, and cell
connectors for loose and broken connections.
(6) Apply thin film of grease to terminal posts, cable
connectors, and cell connectors.