Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
Troubleshooting - CONT
Table 2-2.
Malfunction
Test or Inspection
Corrective Action
WASHER MACHINE- CONT
STEP 3. Check pump belt.
Adjust belt, para. 2-83.
STEP 4. Check for defective pump.
Replace pump, para. 2-87.
DRYER
51. Motor does not run.
STEP 1. Check for tripped circuit breaker.
Reset circuit breaker at galley power panel.
STEP 2. Check motor push switch for lint.
Remove lint.
52. Heater element does not heat.
STEP 1. Check for tripped circuit breaker.
Reset circuit breaker at galley power panel.
STEP 2. Check for defective heater element.
Replace heater element, para. 2-92.
53. Heater element shuts off prematurely.
STEP 1. Check exhaust system for proper installation.
Correct as required.
54. Heater element cycle on/off.
STEP 1. C h e c k lint filter.
Clean lint filter.
STEP 2. Check for lint in internal dryer ductwork.
Clean ductwork.
STEP 3. Check for lint in external exhaust system.
Clean exhaust system.
2-122
|
||