Custom Search
 
  
 
TM 55-1905-223-24-18-1
a.
Repair at the unit level consists of cleaning the inside of the second stage
vessel and replacing the liquid transmitter (7), packing (3). retainer (2),
preformed packing (9) and fluid filter elements (5 and 12).
b.
Thoroughly flush and clean inside of second stage vessel with water.
CAUTION
It is important that filter elements be
handled properly.  DO NOT touch or handle
the sock area (side covering) of the filter
element.  Contamination of this surface by
any oils, including skin oils, may prevent
the filter element from functioning properly
and cause foaming in the effluent.  Handle
filter element only by the end cap. When
installing element, insert hand through
opening on the end cap.
a.
Place fluid filter elements (15) and (12) over the threaded filter support
(6).
Replace and center hold down plate (4) over end cap of top filter element
b.
(5).
Replace preformed packing (3), packing retainer (2), and self-locking wing
c.
nut (1).
There are no
d.
Tighten self-locking wing nut as tightly as possible by hand.
torque requirements.
DO NOT use a wrench to tighten wing nut or
the filter elements will be damaged.
e.
Replace cover (10) and preformed packing (9).
Replace clamp (11) securing cover (10) and tighten. There are no torque
f.
requirements.
Replace liquid transmitter (7).
g.
Remove tags and connect wires to liquid transmitter terminals.
h.
Replace liquid transmitter cover (8).
i.
j.
Remove warning tag from power panel and restore power.