Tweet |
Custom Search
|
|
|
|||||
|
|||||
TM 55-1905-223-24-18-1
c. Remove Filters .
Wait until water has drained below the level
of the cover before opening the cover.
(1) loosen and remove clamp (11, FIGURE 2-23) securing cover (10) to second
stage vessel.
(2) Remove cover (10) and preformed packing (9).
(3) loosen and remove self-locking wing nut (1) from threaded filter support
(6).
(4) Remove packing retainer (2), preformed packing (3) and hold down plate
(4).
(5) Remove fluid filter elements (5) and (12).
(6) Unscrew and remove liquid transmitter cover (8).
(7) Tag and disconnect wires attached to transmitter terminals.
(8) Unscrew liquid transmitter (7).
2-242
|
|||||