Tweet |
Custom Search
|
|
|
|||||
|
|||||
TM 55-1905-223-24-18-1
Remove Rotary Switch.
(Starboard Bulkhead) (FIGURE 2-145)
g.
(1) Remove round head screw (4) and lever (3).
(2) Remove four screws (7) and cover (8).
(3) Tag and disconnect electrical leads (6) to rotary switch.
(4) Remove four round head screws (2) and rotary switch cover (1).
(5) Remove rotary switch (5).
DISASSEMBLY (FIGURE 2-146)
a.
Remove key (4) from side of control unit and insert in keyhole (5) to unlock
nut.
Swing door (9) to the left to open.
b.
Tag and disconnect electrical leads to the following: lamp check push switch
c.
(3), leads (13, 27), horn off push switch (12), leads (15), buzzer (10),
leads (24, 25), collective alarm indicator (8), leads (23), relays (21). and
leads (22).
2-587
|
|||||