Custom Search
 
  
 
TM 55-1905-223-24-18-1
Replace/Repair Power Distribution Panel, Galley P202.
2-160.
This task covers:
a. Removal, b. Repair, c. Replacement.
INITIAL SETUP
Equipment Condition
Tools
Main switchboard GALLEY POWER PANEL
T o o l kit, electrician's,
P202 250RT circuit breaker OFF and
tagged "Out of Service - Do Not
Operate."  TM 55-1905-223-10.
Circuit breaker P/N 360H
Circuit breaker P/N 325H
Circuit breaker P/N Q315H
Circuit breaker P/N Q330H
Circuit breaker P/N Q340H
Warning tag, Item 1, Appendix C
Death, serious injury, or equipment damage
can result from contact with live electrical
c i r c u i t s .  Before beginning work on this, or
any other electrical equipment, turn power
and control voltage circuit breakers OFF and
tag "Out of Service - Do Not Operate."
Refer to the procedures in paragraph 2-159 to replace and repair the power
distribution panel, door assembly, plug in breaker unit, and main interior lug.
Change 1


 


Privacy Statement - Copyright Information. - Contact Us