Custom Search
 
  
 
TM 55-1905-223-24-18-1
Replace/Repair Power Distribution Panel P101.
a. Removal, b. Repair, c. Replacement.
This task covers:
INITIAL SETUP
Equipment Condition
Tools
Main switchboard QTRS HEATER PANEL
T o o l kit, electrician's,
P101 125AT UVT circuit breaker OFF
and tagged "Out of Service - Do Not
Operate."  TM 55-1905-223-10.
Materials/Parts
Circuit breaker P/N Q215HM
Circuit breaker P/N Q22OHM
Circuit breaker P/N Q225HM
Circuit breaker P/N Q230HM
Circuit breaker P/N Q235HM
Thermostat P/N M7D
Warning tags, Item 1, Appendix C
WARNING
Death, serious injury, or equipment damage
can result from contact with live electrical
circuits. Before beginning work on this, or
any other electrical equipment, turn power
and control voltage circuit breakers OFF and
tag "Out of Service - Do Not Operate."
Remove thermostats.
a.
NOTE
Refer to TM 55-1905-223-10 for location of
thermostats.
(1) Remove thermostat cover (3, FIGURE 2-151).
(2) Remove mounting screws (2).
(3) Tag and disconnect wiring from thermostat (1).
(4) Remove thermostat.
2-623