Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
Replace/Repair Floodlights.
2-187.
This task covers:
a. Removal, b. Repair, c. Replacement.
INITIAL SETUP
Equipment Condition
Tools
Associated power distribution panel'
T o o l kit, electrician's,
circuit breaker OFF and tagged
"Out of Service - Do Not Operate."
TM 55-1905-223-10.
Materials/Parts
Lamp ballast P/N INX5023
Floodlight P/N HIDMAGRBWB
Gasket P/N GKT3008
Gasket P/N GKT6024
Lens P/N INX 2125
Mercury vapor lamp P/N INX 3524
Warning tag, Item 1, Appendix C
WARNING
Death, serious injury, or equipment damage
can result from contact with live electrical
c i r c u i t s . Before beginning work on this, or
any other electrical equipment, turn power
and control voltage circuit breakers OFF and
Refer to the procedures in paragraph 2-182 to replace/repair the floodlights.
2-648
Change 1
|
||