Turn door panel screws (2) counterclockwise to loosen.
c.
Swing door panel (12) left to open.
d.
Tag wiring to ammeter (1) FIGURE 2-209), remove nuts (2) from meter terminals
e.
(3) and disconnect wiring.
f.
Remove captive screw (11) and protective switch cover (12).
g.
On rotary switch (9) tag and disconnect wiring to switch terminals (10).
h.
Repeat step e. for rotary switches (7, 8).
i.
Remove nuts (4) one each from four mounting studs on each meter (1, 5, 6, and
j.
14).
k.
Remove meters (3, 4, 10 and 11, FIGURE 2-208 from front of panel door (12).
Remove rotary switch handles (6, 7, and 8) by removing set screw and washer
l.
(13), FIGURE 3-166) from the underneath side of each handle and sliding
handle off shaft.
Remove screws (9) FIGURE 2-208 from rotary switches (6, 7, and 8).
m.
Remove each switch (6, 7, and 8) from rear until shaft clears door panel
n.
(12).
o.
Turn door panel screws (3, FIGURE 2-210) counterclockwise.
Remove door panel (6) using handrail (2).
Store panel (5) in safe and out-
p.
of-way place.
NOTE
For disassembly of circuit breaker (1, 4,
and 5 FIGURE 2-210) refer to paragraph 2-
Disassemble circuit breakers (1, 4, and 5).
q.
Repair is by replacement of light indicators (1, 5 FIGURE 2-208), meters (3, 4,
10, 11), rotor switches (6, 7, and 8 FIGURE 2-209), circuit breakers (1, 4, and
5, FIGURE 2-210 and lamps.
Install incandescent lamps into each light lens (1, 5, FIGURE 2-208) socket.
a.
2-864
|
||