Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair at this level of maintenance is by replacement of the threaded fittings in
the potable water piping system.
NOTE
Coat threads of all fittings with anti-seize
compound.
I n s t a l l fittings in piping.
a.
( 1 ) Install coupling (2) on inlet piping (3).
(2) Connect union (6) to tee (4).
( 3 ) Install tee (4) on inlet piping (3).
( 4 ) Install outlet piping (5) on tee (4).
(5) Connect outlet piping (5) at union (6) by holding tail piece (7) of union
(6) and turning collar (8) clockwise.
b. Operational check.
(1) Remove warning tags.
(2) Open shutoff valves (1) and (9).
(3) Operate system; refer to TM 55-1905-223-10.
(4) Check for leaks in system and retighten connections as necessary.
2-961


 