Custom Search
 
  
 
TM 55-1905-223-24-18-1
MAINTENANCE OF PIPING SYSTEM, COMPRESSED AIR
Repair Threaded Valves.
This task covers: Repair.
At Auxiliary Machinery Motor Control
Tool kit, general mechanic's,
Center, press Air Compressor No. 1
and No. 2 STOP pushbuttons, set
circuit breakers to OFF position.
Materials/Parts
Tag switches "Out of Service - Do
Not Operate."
Piping system, compressed air
P/N 8551031, refer to
TM 55-1905-223-24P
General Safety Instructions
Anti-seize compound, Item 15,
Appendix C
Warning tags, Item 1, Appendix C
WARNING
Utility pail,' Item 13, Appendix C
Ensure system is turned OFF and
q
tagged to prevent operation during
maintenance.  Generated pressure
could cause injury.
Use extreme care when breaking
q
system connections.  Escaping
pressure and/or fluids could cause
injury.
Clean up spills immediately.
q
Spills create an unsafe working
area.
Refer to paragraph 2-319 for procedures.