Tweet |
![]()
Custom Search
|
|
![]() |
||
![]() TM 55-1905-223-24-18-2
Table 3-1. Preventive Maintenance Checks and Services
D - Daily
W - Weekly
M -Monthly
Q - Quarterly
S - Semiannually
A - Annually
Item
Intervals
Items To Be
No.
DWMQS
A
Inspected/Serviced
Procedures
9
Tank Level
TANK LEVEL INDICATOR SYSTEM - CONT
Indicator
System
NOTE
Receiver
Module Gasket DO NOT secure cover at this time.
-
CONT
10
Tank Level
Inspect for tightness and evidence of burning. Replace
Indicator
defective blocks as specified in paragraph 3-41 or 3-42.
System
Terminal
Blocks
11
Tank Level
Inspect for tightness, cracks, and breakage. Replace
Indicator
defective modules and connectors as specified in paragraphs
System
Printed
Circuit
Models and
Connectors
12
Tank Level
Inspect for tightness, cracks, and blisters. Replace
Indicator
defective capacitors as specified in paragraph 3-44 or 3-
System
45, or 3-46.
Capacitors
13
Tank Level
Inspect for evidence or burning or swelling and
Indicator
tightness. Replace defective transformers as specified
System
in paragraph 3-44 or 3-45, or 3-46.
3-5
|
||
![]() |