Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-44. Replace/Repair Receiver Module RE-39240.
This task covers:
a. Removal
b. Disassembly,
c. Repair
d. Assembly
e. Replacement
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanic's,
Electrical power to tank level
indicator system turned OFF at
Panel L102. Tag switch "Out of Service - Do Not
Operate."
Materials/Parts
Receiver module RE-39240-7/M1-M7-38100
Gasket P/N 37044, 37047
Meter assembly P/N 43075
Preformed packing P/N 17287, 23273
Toggle switch P/N MS24659-22D, 30054
Sonalert alarm P/N 39713
Card guide P/N 37096
Printed circuit connector P/N 32962
Power supply P/N 38005
Flasher module P/N 38105
Circuit card assembly P/N 38100
Simulator float P/N 37084
Wire wound variable resistor
P/N RV4SAYSB252A
Knob P/N 22423
Nonmetallic grommet P/N 30674
Power transformer P/N 37652, 37653
Electrolytic fixed capacitor P/N 37079
Warning tags, Item 1, Appendix C
REMOVAL
a. Tag and disconnect electrical cable connectors at top of box assembly (4).
b. Remove six plain hex nuts (3) lockwashers (2) and hexhead capscrews (1) securing receiver module
box assembly to support mount.
c. Remove box assembly.
3-163


 