Tweet |
Custom Search
|
|
|
|||||
|
|||||
TM 55-1905-223-24-18-2
Table 3-2. Troubleshooting-CONT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WASHER MACHINE - CONT
STEP 7. Check door switch.
Replace switch (para. 3-92).
STEP 8. Check motor.
Replace motor if defective (para. 3-102).
STEP 9. Check for operating transmission.
Replace transmission (para. 3-99).
33. No cold water.
STEP 1. Check cold water mixing valve solenoid.
Replace solenoid if defective (para. 3-93).
STEP 2. Check cold water supply hose.
Straighten or replace supply hose (para. 3-100).
STEP 3. Clogged mixing valve screen.
Clean or replace screen (para. 3-93).
STEP 4. Check that timer advances.
Replace timer if defective (para. 3-92).
STEP 5. Check temperature switch.
Replace switch if defective (para. 3-92).
STEP 6. Check pressure switch.
Replace switch if defective (para. 3-92).
STEP 7. Check loose or broken wires.
Replace or tighten wires.
34. No hot water.
STEP 1. Check hot water mixing valve solenoid.
Replace solenoid if defective (para. 3-93).
STEP 2. Check hot water supply hose.
Straighten or replace supply hose (para. 3-100).
STEP 3. Clogged mixing valve screen.
Clean or replace screen (para. 3-93).
STEP 4. Check timer.
Replace timer if defective (para. 3-92).
3-31
|
|||||