Custom Search
 
  
 
TM 55-1905-223-24-18-2
Table 3-2. Troubleshooting-CONT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
SOLID WASTE COMPACTOR - CONT
29. Unit operates but is noisy.
STEP 1. Check adjustment of drive chain.
Adjust drive chain. Should have 1/4" deflection.
STEP 2. Check lubrication of power screws and triangle bearing.
Lubricate as required.
30. Drawer will not open. (Ram is part way down).
STEP 1. Check for broken chain.
Replace chain (para. 3-83).
STEP 2. Check door or drawer safety switch with multimeter
Replace defective switch(es), para. 3-90.
31. Unit will not shut off.
STEP 1. Check top limit switch with multimeter.
Replace top limit switch (para. 3-83).
STEP 2. Check start/stop switch with multimeter
Replace start/stop switch (para. 3-83).
WASHER MACHINE
32. No agitation.
STEP 1. Check drive belt.
Adjust or replace (para. 3-102).
STEP 2. Check for sheared motor pulley drive pin.
Remove motor and replace drive pin (para. 3-102).
STEP 3. Check for binding in pump.
Clean or replace pump (para. 3-100).
STEP 4. Check that timer advances.
Replace timer if defective (para. 3-92).
STEP 5. Check sensitive switch.
Replace switch if defective (para. 3-92).
STEP 6. Check pressure switch.
Replace switch if defective (para. 3-92).
3-30


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business