Custom Search
 
  
 
TM 55-1905-223-24-18-2
ay. Remove screen (99).
az. Remove handle (100).
REPAIR
Repair at this level of maintenance is by replacement of circulating fan (23, Sheet 1), electromagnetic relay
(27), time totalizing meter (4), ammeter (9), electro-magnetic relay (32, Sheet 2), metallized, paper-plastic
dielectric fixed capacitor (41), cartridge fuse (49), electrolytic fixed capacitor (50), power transformer (61),
cartridge fuse (60), rectifier assembly (80), choke assembly (81), and resistor assembly (69).
ASSEMBLY
a. Install handle (100, Sheet 3).
b. Install screen (99).
c. Install insulator (98) and setscrew (97).
d. Install lockwasher (94) and machine screw (93).
e. Install clamp (92).
f. Install steel plate (91).
g. Install lockwasher (96) and hexagon head capscrew (95).
h. Install chock assembly (81, Sheet 2).
i. Install lockwashers (77, 83) and hexagon nuts (76, 82).
j. Install flat washers (75, 86), lockwashers (74, 85), and hexagon head capscrews (73, 84).
k. Install rectifier assembly (80).
1. Install lockwasher (79) and hexagon nut (78).
m. Install electrolytic fixed capacitor (68).
n. Install clamp (72), lockwasher (71), and machine screw (70).
o. Install resistor (69).
p. Install deflector (62).
q. Install insulator (58) and fuse block (57).
r. Install cartridge fuse (60).
3-230


 