Custom Search
 
  
 
TM 55-1905-223-24-18-2
3-148. Replace/Repair Forward Deck Machinery Motor Control Center, Power Distribution.
This task covers:
a. Removal,
b. Repair,
c. Replacement.
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, electrician's,
Main switchboard FWD DECK MCHRY MCC
P206 200AT circuit breaker OFF and
tagged "Out of Service - Do Not
Materials/Parts
Operate." (TM 55-1905-223-10).
Warning tags, Item 1, Appendix C
WARNING
Death, serious injury, or equipment damage can result from
contact with live electrical circuits. Before beginning work on
this, or any other electrical equipment, turn power and control
voltage circuit breakers OFF and tag "Out of Service - Do Not
Operate."
NOTE
Repair and replacement of motor control centers is covered in
the control centers switchboards section of this manual.
REMOVAL
a. Disconnect electrical cable (1 through 16) from motor control center.
b. Disconnect electrical cable from termination.
REPAIR
Repair at this level of maintenance is by replacement of electrical cables.
REPLACEMENT
a. Connect electrical cable (1 through 16) to motor control center.
b. Connect electrical cable to termination.


 