TM 55-1905-223-24-18-2
This task covers:
a. Removal
b. Disassembly
c. Repair
d. Assembly
e. Replacement
INITIAL SETUP
Tools
Tool kit, general mechanic's,
Materials/Parts
Sealing tape P/N 91-7790-0000
Adhesive sealant P/N 91-0047-0000
Glazing gasket P/N KS-16184
Rubber strip P/N 1140
Window glass (heat treated)
P/N KS-25537-8
Window glass (wire insert)
P/N KS-25537-9
REMOVAL
WARNING
Care must be taken while handling windows to prevent
personal injury or equipment damage.
a. Support fixed windows (4, Figure 3-177).
b. Remove self-locking nuts (1), capscrews (2), and flat washers (3).
c.
Remove fixed windows (4) from bulkhead.
DISASSEMBLY
a. Clean off old adhesive sealant (1, Figure 3-178) and sealing tape (2) from
around bulkhead opening.
b. Remove glazing gaskets (6, 7) from window frames (3, 10).
c.
Carefully remove (heat treated) window glass (5) and (wire inserted) window
glass (8) from window frames (3, 10).