Tweet |
Custom Search
|
|
|
|||||
|
|||||
TM 55-1905-223-24-18-2
4-22. Repair Sensor Manifold. (Figure 4-12 Sheets 1 and 2)
This task covers:
a. Disassembly,
b. Repair,
c. Assembly.
INITIAL SETUP :
Tools
Equipment Condition
Tool kit, general mechanic's,
Sensing module assembly removed as
specified in paragraph 3-33 .
Tool kit, electrician's,
Materials/Parts
Sensor manifold P/N 335-E
DISASSEMBLY
a. Position sensor manifold on clean flat surface.
b. Photo diode.
(1) Remove four machine screws (17).
(2) Remove sensor end cap (16) and preformed packing (15).
(3) Tag and desolder photo diode leads from terminals 5, 6 and 7 on terminal board (18).
(4) Unscrew and remove retainer plug (7) and preformed packing (5).
(5) Lift diode retainer (3) out of housing (20).
(6) Lift photo diode (2) and wire leads out of housing.
(7) Lift diode support (1) preformed packing (36) and side window (31) out of housing.
c. Side window.
(1) Remove four machine screws (27),
(2) Remove light detector cap (28) and preformed packing (29).
(3) Remove light spacer (32) light pad (33) side window (25) and preformed packing (26).
Change 1
|
|||||