Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-2
Table 2-1. Preventive Maintenance Checks and Services-CONT
D-Daily
W-Weekly
S-Semiannually
A-Annually
Item
Interval
Items To Be
No
D
W
S
A
Inspected/Serviced
Procedures
6
Oil filters-Continued
(8) Replace filter body bolts (4).
(9) Repeat procedure for other filter element.
7
Exterior bolts
Inspect all bolts and nuts. Replace any that are stripped or have
rounded heads. Repair any stripped nut holes in the housing by
installing helicoils. Check for tightness.
8
Mountings
Inspect mountings for cracks. Repair as necessary by welding. Ensure
that mounting bolts are in good condition and secure.
9
Oil (See Note 2
Change oil. The reduction gear is provided with a manually operated
sump pump located at the right rear of the propulsion engine, mounted
to the flywheel housing. The input side of the pump is connected to the
engine and gearbox sumps. The output side of the pump is connected
to the dirty lube oil tank. To change oil, proceed as follows:
WARNING
Spilled liquids create very hazardous decks and passageways.
Slippery deck plates and walkways around operating machinery
increases risk of injury from falls and moving machinery. Clean up
spills right away.
Change 2
2-7
|
||