CAUTION
Ensure that all wiring and cables are tagged with their locations
recorded as they are removed from the generator terminal box.
(2) Disconnect and tag all external cables from inside the terminal box.
(3) Remove the disconnected cables and their c nduits from the generator terminal box. Ensure that
o
you record the location where each cable and conduit is removed from the terminal box. Each
cable must be returned to the same location on replacement generator set when it is installed.
(4) Tag and disconnect all control wiring attached to the voltage regulator.
c.
Disconnect hoses, lines, and electrical wiring to the engine assembly as follows:
NOTE
Tag all hoses, lines, and electrical wiring connections as they
are removed. This will identify their locations on installation of
replacement engine.
(1) Close the following external valves:
(a) Fuel supply line valve.
(b) Fuel drain line valve.
(c) Clean oil supply line valve.
(d) Dirty oil drain line valve.
NOTE
Coolant supply, drain, and vent line valves should have been
closed when draining the cooling system.
(2) Disconnect starter motor.
(a) Disconnect the external wiring and cables on electrical starting motor/magnetic switch group
(b) Disconnect air supply lines to engine air starter (paragraph 2-24).
(3) Disconnect and tag all external electrical wiring to the instrument panel, fuel pump governor
control.
(4) Remove the inlet connection to the fuel filter group (paragraph 2-31) and drain excess fuel from the
engine.