Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-5
ASSEMBLY
a.
Install the pipe plugs, fuel inlet, and fuel drain fittings into the fuel passage.
(1) Make sure the fittings and plugs are installed in their original location.
(2) Apply teflon tape or liquid lead compound to the threads.
(3) Tighten the pipe plugs to the torque value given in Table 4-6.
Table 4-6. Pipe Plug Torque-ft-lb. (N )
m
Plug Size
Minimum
Maximum
Inch
1/16
3 (4)
6 (8)
1/8
5 (7)
10 (14)
3/8
35 (47)
45 (61)
1/2
60 (81)
70 (95)
3/4
65 (88)
75 (102)
1
135 (182)
145 (197)
(4) Apply a coat of expansion plug sealant to the outside diameter of the expansion (cup) plug. Apply a
coat of the sealant to the inside diameter at the water hole.
(5) Use the correct expansion plug driver to install the expansion plug (cup) plug.
NOTE
If you do not have expansion plug drivers, you can use a mandrel of the correct size to install the
plug. Install the plug so that it will be even with 0.090 inch (2.29 mm) below the chamber,
FIGURE 4-15. Do not push the plug to the bottom of the counterbore.
o Apply clean lubricating oil to the valve stems.
4-29
|
||