Custom Search
 
  
 
TM 55-1905-223-24-5
c. Inspect crankshaft:
(1) Check the crankshaft for wear, cracks, and other damage.
(2) Using micrometer, measure each journal of the crankshaft in three places and take the average of
those three measurements.
(3) Grind the crankshaft journals if they are out-of-round more than 0.002 inch (0.05 mm) (or replace the
crankshaft) (See Table 4-9 for minimum and maximum diameters.) Follow the instructions provided-
with the grinding equipment.
FIGURE 4-47. Front Counterweight Markings.
Table 4-9. Crankshaft Journal Diameters
Minimum
Maximum
Worn Limit
Journal
Inch (mm)
Inch (mm)
Inch (mm)
Connecting Rod
3.1235
3.125
3.122
(79.337)
(79.375)
(79.298)
Main Bearing
4.4985
4.500
4.4975
(114.262)
(114.30)
(114.237)
4-89


 