TM 55-1905-223-24-5
FIGURE 4-58.
Measuring Counterbore.
CAUTION
A concave condition in the counterbore can cause liner breakage.
4 Measurement 2 must never exceed measurement 1 (concave) or be less than measurement 1 (convex) by
more than 0.0014 inches (0.036 mm).
(3) Install the cylinder sleeves (liners).
NOTE
Be sure that the cylinder block and all parts are clean before
assembly. If used liners are being installed again, any shims (5,
Lubricate preformed packing with vegetable oil. Do not use
lubricating oil on preformed packing because they will increase in
size after they have been lubricated.
4-103