Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-9
2-20. Replace/Repair Coil Assembly (FIGURE 2-11)
This task covers:
a. Removal,
b. Repair,
c. Replacement
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
TM 55-1905-223-10. Equipment shut down,
tagged "Out of Service - Do Not Operate."
Tool kit, electrician's,
Refer to the following paragraph in
this maintenance manual:
Solenoid valve removed (paragraph
Materials/Parts
2-19).
Seal washer, P/N 610-011
Spring pin, P/N 51-170015
Coil, P/N 400827
Preformed packing, P/N 11-106013
Electrical connector plug, P/N 610-009
REMOVAL
a. Remove four machine screws (1) securing cover to solenoid valve (3). Remove cover (2).
b. Remove spring pin (4).
c. Tag and remove electrical wires (5).
d. Remove machine screws (6) and remove coil (7).
e. Remove electrical plug connector (9) and seal washer (8).
f. Remove and discard preformed packing (10).
REPAIR
Repair at this level consists of replacing: seal washer (8), spring pin (4), coil (7), preformed packing (10), and
electrical plug connector (9).
REPLACEMENT
a. Install preformed packing (10).
Change 1
2-37
|
||