b. Replace seal washer (8) and secure electrical plug connector (9).
c. Position coil (7) in solenoid valve assembly (3) and secure machine screws (6).
d. Connect electrical wires (5) and remove tags.
e. Replace spring pin (4).
f. Secure cover (2) to solenoid valve assembly (3) with four machine screws (1).
g. Install solenoid valve (paragraph 2-19).
h. Restore power to pumpset.
i. Restore equipment to normal operation (TM 55-1905-223-10).
j. Remove "Out of Service - Do Not Operate" tag from circuit breaker.
FIGURE 2-11. Coil Assembly.