(2) Open the valve and drain reservoir.
(3) Close drain valve.
(4) Properly dispose of used hydraulic fluid.
b. Clean
(1) Remove the reservoir end cover (4).
(2) Reach into the reservoir and unscrew the suction strainer (1).
(3) Clean (or replace if you need to) the strainer.
(4) Rinse out reservoir interior with solvent and wipe dry.
(5) Install suction strainer (1).
(6) Install the reservoir end cover (4).
(7) Remove and clean or replace filler/breather (3).
c. Fill
(1) Remove filler/breather (3) from reservoir.
(2) Fill the reservoir with clean, filtered hydraulic fluid.
(3) Install the filler/breather (3).
(4) Wipe up any spillage.
(5) Repeat the entire procedure for the other reservoir.
(6) Return unit to normal operation (TM 55-1905-223-10).
REPAIR
Repair consists of replacement of the suction strainers (1), level sensors (2) or filler/breather (3).
Hulls 2008 and subsequent
Change 1 2-45


 