Section XIII. FIRE PROTECTION SYSTEM
Zone 4 (Continued)
Location
Temperature Setting
Galley
160F (2)
Provisions Storeroom
160F
Emergency Generator Room
225F (2)
Steering Gear Room
160F
Zone 5
Location
Temperature Setting
Laundry Room
160F
Crew Stateroom
160F
Crew Stateroom
160F
Crew Stateroom
160F
Crew Stateroom
160F
Engineer's Stateroom
160F
Master' s Stateroom
160F
Zone 6
Location
Temperature Setting
Pilothouse
160F
Pilothouse
160F
Pyro Locker
140 F
e. Manual fire alarm stations. There are 12 manual fire stations installed on the LCU. These
manually operated "pull down" lever units allow the reporting of a fire from various locations on the vessel.
The action of the lever closes a normally open contact which will activate a 10-inch bell in the Pilothouse.
No.
Location
1
Pilothouse (Starboard)
2
01 Level (Starboard Passageway), Frame 47
(outside Laundry Room)
3
01 Level (Starboard Passageway), Frame 39
4
Main Deck (Starboard Passageway), Frame 38
5
Provisions Storeroom
6
Emergency Generator Room
7
Frame 34 (Starboard), outside Recreation Room
8
Galley
9
Bowthruster Room
10
Tunnel (Centerline), Frame 25
11
Steering Gear Room
12
Machinery Space
|
||