Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0026 00
Operation from the Port Stowage Locker
WARNING
Although the FM-200 agent used in the fire suppression system is considered non-toxic
to humans in concentrations necessary to extinguish most fires, personnel should not
be unnecessarily exposed to the agent. When FM-200 is exposed to temperatures over
approximately 1300 F (704.4 C), Hydrogen Fluoride (HF) gas is formed. This HF gas is
toxic to humans. Do not allow FM-200 agent or its byproducts to come in contact with
personnel. Failure to comply could result in serious injury or death.
1.
Ensure that no personnel are present in the engine room.
2.
Remove the locking pin (11). This will break the seal wire (12).
3.
Pull the local manual release lever (13). The fire suppression agent is now discharged into the engine room.
13
12
11
0026 00-3
|
||