Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0053 00
ITEM
INTERV L
A
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
45
Oily Water
Collection System
Before
2.0
a. Piping, Valves,
Inspect piping, valves, strainers, hoses Class III leakage noted.
Strainers, Hoses, and fittings for leakage and damage.
and Fittings
Ensure that all valves operate freely
Valves not free.
through entire range of motion. Ensure
that hand pump and discharge hoses
are properly stowed. Ensure that tank
discharge fittings are capped.
Before
1.0
b. Waste Oil Tank
Inspect oily water tank for cracks, leaks, Class III leakage noted.
or corrosion. Inspect sight gauge for
leakage or damage. Inspect piping
connections for tightness.
46
Firefighting and
Ballast System
Before
0.2
a. Piping, Valves,
Inspect piping, valves, strainers, hoses, Class III leakage noted.
Strainers, Hoses, and fittings for leakage and signs of
and Fittings
damage.
Before
1.0
b. Fire Pump
Inspect fire pump for leakage or
Class III leakage noted.
damage. Check drive shaft and flanges
for loose fasteners. Tighten fasteners
as necessary.
Before
0.5
c. Electric Clutch
Inspect clutch for loose fasteners or
Wiring damaged.
damage. Tighten fasteners as required.
Inspect wiring for damage and proper
routing.
47
Before
0.2
Hoses, Nozzles,
Inspect hoses and nozzle for secure
Hose or nozzle damaged.
etc.
mounting and damage. Ensure that
nozzle is not obstructed.
Nozzle obstructed.
ACCOMMODA-
TION MODULE
48
Before
0.1
Batteries and
Check batteries for leaks and corrosion. Battery leaking.
Cables
Check cables for tight, clean connec-
tions. Check battery mounting for
Cable or connection
secure fit.
badly corroded.
Battery loose in mount.
49
Before
0.3
24 V Control and
Inspect panel to ensure that all breakers Switch or breaker will
Distribution Panel
and switches have full range of motion. not move.
Ensure that all breakers and switches
are present and function properly.
Switch or breaker
missing.
0053 00-9
|
||