Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0053 00
ITEM
INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
36
Before
0.1
Fuel Filter/Water
Inspect filter and connections for leaks. Class I, II, or III leakage
Inspect the clear bowl for accumulation noted.
of filtered deposits or water.
Bowl is cracked or
broken.
37
Before
0.2
Fuel Piping,
Inspect piping, valves, hoses, and
Class I, II, or III leakage
Valves, Hoses, and fittings for leaks or damage.
noted.
Fittings
38
Engine Cooling
System
Before
0.5
a. Piping, Hoses
Inspect pipe joints and hose connec-
Class III leakage noted.
and Valves
tions for cracks or leaks.
0.5
Tighten hoses or hose clamps as
necessary.
Before
0.1
b. Expansion Tank
Inspect sight glass for coolant level
Class III leakage noted.
(1/2 full when cold). Replenish coolant
as necessary. Check tank for cracks,
Tank is not securely
leaks, or corrosion.
mounted.
39
Before
0.2
220/110 V Wiring
Visually inspect 220/110 V wiring for
Wiring insulation is
signs of wear, damaged insulation, and
missing, exposing bare
proper routing.
conductor.
40
Before
0.5
220/110 V Control
Inspect panel to ensure that all breakers Switch or breaker will
and Distribution
and switches have full range of motion. not move.
Panel
Ensure that all breakers and switches
are present and function properly.
Switch or breaker
missing.
41
Before
0.2
Power Transformer Check that transformer is mounted
Transformer is not
220 to 110 V
securely. Visually check wiring at
mounted securely.
transformer for wear, damaged
insulation, and proper routing.
Wiring insulation is
missing, exposing bare
conductor.
42
Before
0.2
Fire Detection
Ensure that flame detectors are securely Detector obstructed.
System
mounted and free from obstruction.
Check wiring for damage.
Wiring damaged.
43
Before
0.5
Air Conditioning
Inspect air conditioner raw water piping Class III leakage noted.
Raw Water Piping, valves, strainers, hoses, and fittings for
Valves, Strainers,
leakage and damage.
Hoses, and
Fittings
Before
2.0
Disassemble and clean the strainer.
44
Before
0.5
Air Conditioning
Inspect pump for secure mounting,
Class III leakage noted.
Raw Water Pump
leaks, and damage.
0053 00-8
|
||