TM 55-1905-242-14
0079 00
INSTALLATION--GAUGES WITH ELECTRIC SENDERS
1.
Procure a new gauge.
2.
Insert the new gauge (4) into its hole in the gauge panel (2).
3.
Slide the gauge clamp bracket (6) into place and secure it to the back of the gauge (4) with nuts (5).
4.
Install the gauge wiring (3).
5.
Proceed to the Installation--All Gauges procedure in this work package.
INSTALLATION--DIRECT-READING GAUGES
1.
Procure a new gauge.
2.
Insert the new gauge (4) into its hole in the gauge panel (2).
3.
Slide the gauge clamp bracket (6) into place and secure it to the back of the gauge (4) with nuts (5).
4.
Dispose of used oil and contaminated parts in accordance with local regulations.
5.
Attach the connectors (8), if required, and the line (7) to the gauge (4).
6.
Install the gauge wiring (3), if any.
7.
Proceed to the Installation--All Gauges procedure in this work package.
INSTALLATION--ALL GAUGES
1.
Position the gauge panel (2) in place on the console and secure it with screws (1).
2.
Remove the lockouts and tagouts and check the operation of the gauge.
END OF WORK PACKAGE
00790079 00-3