Custom Search
 
  
 
TM 55-1905-242-14
0080 00
REMOVAL--HYDRAULIC GAUGES (continued)
8.
If any adapters (12) are installed in the gauge (8), remove these adapters.
11
8
10
1
2
0
10
10
20
20
30
30
40
R
WAGNE
40
12
9
7
3
INSTALLATION--HYDRAULIC GAUGES
1.
Procure a new gauge.
2.
If any adapters (12) were removed from the old gauge (8) during Removal--Hydraulic Gauges, install them on the new
gauge.
3.
Insert the new gauge (8) into its hole in the gauge panel (2) and secure it with the gauge clamp bracket (11) and nuts (10).
4.
Install the line (9) onto the back of the gauge (8).
5.
Install the wiring (7) to the back of the gauge (8) using the labels from step 3 of Removal--Hydraulic Gauges as a guide.
6.
Position the gauge panel (2) onto the console (3) and secure it with the screws (1).
7.
Remove the lockouts and tagouts, test the operation of the gauge, and check for leakage.
8.
Dispose of used hydraulic fluid and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE
0080 00-3/4 blank
0080 00-3


 


Privacy Statement - Copyright Information. - Contact Us