Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0080 00
REMOVAL--RUDDER ANGLE INDICATOR (Continued)
5.
Remove the gauge (5) from the gauge panel (2).
6
5
1
0
10
10
20
20
30
30
40
ER
40
WAGN
4
3
2
INSTALLATION--RUDDER ANGLE INDICATOR
1.
Procure a new gauge (5).
2.
Insert the gauge (5) into its hole in the gauge panel (2).
3.
Secure the gauge (5) to the gauge panel (2) with the screws (6).
4.
Install the wiring (4) on the back of the gauge (5) using the labels from step 3 of Removal--Rudder Angle Indicator as a
guide.
5.
Position the gauge panel (2) on the console (3) and secure it with the screws (1).
6.
Remove the lockouts and tagouts and check the operation of the gauge.
REMOVAL--HYDRAULIC GAUGES
1.
Remove the screws (1) that attach the gauge panel (2) to the console (3) and lift the gauge panel away from the console.
2.
Set the multimeter to the Vdc (Volts direct current) setting and check for voltage on all of the gauges. If no voltage is
noted, proceed to the next step. If voltage is noted, ensure that the system is properly secured, locked out, and tagged
out.
3.
Label and remove the wiring (7) from the back of the gauge (8).
4.
Don chemical protective gloves and goggles.
5.
Place a wiping rag or a suitable drain pan beneath the gauge (8) to catch any fluid that might drip. Remove the line (9)
from the back of the gauge (8).
6.
Remove the nuts (10) that secure the gauge clamp bracket (11), and slide the bracket off the gauge (8).
7.
Remove the gauge (8) from the gauge panel (2).
0080 00-2
|
||